ZHUANG Xiaozhou, LIU Xiaoyong, CAI Muwei, YE Lihe. Etiological investigation on occupational chronic benzene poisoning of maintenance workers in an oil storage and transportation enterprise[J]. Occupational Health and Emergency Rescue, 2017, 35(3): 249-251. DOI: 10.16369/j.oher.issn.1007-1326.2017.03.016
Citation: ZHUANG Xiaozhou, LIU Xiaoyong, CAI Muwei, YE Lihe. Etiological investigation on occupational chronic benzene poisoning of maintenance workers in an oil storage and transportation enterprise[J]. Occupational Health and Emergency Rescue, 2017, 35(3): 249-251. DOI: 10.16369/j.oher.issn.1007-1326.2017.03.016

某石油储运企业维修工人职业性慢性苯中毒发病原因调查

Etiological investigation on occupational chronic benzene poisoning of maintenance workers in an oil storage and transportation enterprise

  • 摘要:
    目的 对某石油储运企业维修工人群发职业性苯中毒事故开展调查, 为同类事故的职业病诊断、事故原因调查和处置提供思路。
    方法 结合职业卫生现场调查和应急健康检查的方法, 识别职业病危害因素, 对维修工人进行职业病诊断, 分析事故原因并提出处置建议。
    结果 该企业的储运产品为混合芳烃、柴油等, 其中柴油和原油中苯质量分数分别为0.009和0.107, 虽然工作场所各岗位的空气中苯均未检出, 仍不能排除2名患者的苯职业接触史; 临床资料显示医学观察期间两名患者血常规检查示中性粒细胞计数大多低于1.5×109/L。结合事故现场的调查资料, 综合分析该2名患者的临床表现和健康检查结果、职业史以及职业病危害接触史, 依据《职业性苯中毒的诊断》(GBZ 68-2013), 2名患者均被诊断为职业性慢性中度苯中毒(中性粒细胞减少症)。
    结论 石油储运企业维修工人发生职业中毒的危险大且隐匿性强, 对事故现场调查和监督执法提出了新的挑战。应从监管原料来源、强化防护意识、制定监督办法等方面, 避免同类事件的发生。

     

/