张爱华, 董明, 罗晓婷, 吴邦华, 杨展鸿. 一起误服电镀废液引起铜中毒事故的分析检测[J]. 职业卫生与应急救援, 2017, 35(6): 561-563. DOI: 10.16369/j.oher.issn.1007-1326.2017.06.022
引用本文: 张爱华, 董明, 罗晓婷, 吴邦华, 杨展鸿. 一起误服电镀废液引起铜中毒事故的分析检测[J]. 职业卫生与应急救援, 2017, 35(6): 561-563. DOI: 10.16369/j.oher.issn.1007-1326.2017.06.022
ZHANG Aihua, DONG Ming, LUO Xiaoting, WU Banghua, YANG Zhanhong. Detection of copper in an intoxication accident caused by ingesting electroplating wastewater[J]. Occupational Health and Emergency Rescue, 2017, 35(6): 561-563. DOI: 10.16369/j.oher.issn.1007-1326.2017.06.022
Citation: ZHANG Aihua, DONG Ming, LUO Xiaoting, WU Banghua, YANG Zhanhong. Detection of copper in an intoxication accident caused by ingesting electroplating wastewater[J]. Occupational Health and Emergency Rescue, 2017, 35(6): 561-563. DOI: 10.16369/j.oher.issn.1007-1326.2017.06.022

一起误服电镀废液引起铜中毒事故的分析检测

Detection of copper in an intoxication accident caused by ingesting electroplating wastewater

  • 摘要:
    目的 对一起误服电镀废液而中毒病人的血样、尿样进行快速检测, 确定中毒物。
    方法 电镀废液稀释一定倍数后直接进样, 采用火焰原子吸收光谱法进行检测。病人的血样和尿样用稀释液稀释一定倍数后, 利用电感耦合等离子体质谱法(ICP-MS)对其进行半定量扫描和定量分析。
    结果 电镀废液中铜的质量浓度为84 050 mg/L, 质量分数为8.41%, 锌的质量浓度为37.33 mg/L, 质量分数为0.04%。病人血样铜和锌的质量浓度分别为936.2 μg/L和3 274.0 μg/L, 尿样中铜和锌的质量浓度分别为3 034.0 μg/L和4 055.5 μg/L。
    结论 确定该中毒事故是由误服电镀废液中铜离子导致的铜中毒。电镀废液的组成很复杂, 如何以最快的速度确定目标毒物, 需要选择合适的检测方法。

     

/