张雪梅, 曹思愈, 田河. 溶剂解吸-气相色谱法对工作场所空气中正戊醇检测方法研究[J]. 职业卫生与应急救援, 2018, 36(1): 59-61. DOI: 10.16369/j.oher.issn.1007-1326.2018.01.018
引用本文: 张雪梅, 曹思愈, 田河. 溶剂解吸-气相色谱法对工作场所空气中正戊醇检测方法研究[J]. 职业卫生与应急救援, 2018, 36(1): 59-61. DOI: 10.16369/j.oher.issn.1007-1326.2018.01.018
ZHANG Xuemei, CAO Siyu, TIAN He. Study on methods for determination of amyl alcohol in air of workplaces by dissolved desorption-GC[J]. Occupational Health and Emergency Rescue, 2018, 36(1): 59-61. DOI: 10.16369/j.oher.issn.1007-1326.2018.01.018
Citation: ZHANG Xuemei, CAO Siyu, TIAN He. Study on methods for determination of amyl alcohol in air of workplaces by dissolved desorption-GC[J]. Occupational Health and Emergency Rescue, 2018, 36(1): 59-61. DOI: 10.16369/j.oher.issn.1007-1326.2018.01.018

溶剂解吸-气相色谱法对工作场所空气中正戊醇检测方法研究

Study on methods for determination of amyl alcohol in air of workplaces by dissolved desorption-GC

  • 摘要:
    目的 建立工作场所空气中正戊醇溶剂解吸-气相色谱检测的方法。
    方法 溶剂解吸-气相色谱法, 以正丁醇-二硫化碳溶液(体积比1:100)作为解吸液, 采用0.32 mm×30 m FFAP毛细管气相色谱柱、氢火焰离子化检测器(flame ionization detector, FID)对正戊醇进行检测。
    结果 本方法正戊醇的检出限为1.3 μg, 相关系数r>0.999, 精密度为2.4%~7.7%, 不同浓度回收率在96.1%~101.1%之间, 采样效率100%, 解吸效率为92.3%, 正戊醇穿透容量>6.1 mg; 样品在常温下可保存7 d。
    结论 该方法操作方便, 准确可靠, 可以用于工作场所空气中正戊醇的测定。

     

/

返回文章