  • 摘要:
    目的 对某抽油机组装车间电焊烟尘职业接触情况进行分析,为同类企业通风设施设计提供依据。
    方法 对该车间进行现场职业卫生学调查,检测作业场所空气中电焊烟尘浓度和通风设施风速,并对该场所粉尘作业进行分级。
    结果 该车间电焊岗位操作人员电焊烟尘时间加权平均浓度为(5.75 ±2.35)mg/m3,短时间接触浓度为(8.7 ±1.37)mg/m3,超限倍数在1.6~2.9之间,12个焊接工位中9个不符合国家限值标准,超标率75%。排风口平均风速为(2.30 ±0.17)m/s,排风口距焊接工位平均距离(4.60 ±0.92)m,各焊接工位控制点平均风速为(0.30 ±0.08)m/s,8个工位粉尘作业分级为Ⅰ级(轻度危害作业)。
    结论 该组装车间电焊烟尘浓度及超限倍数超过职业卫生接触限值的要求,超标主要原因是通风设施除尘效果较差,应对其通风除尘设施加以改造,并加强职业卫生管理,降低电焊烟尘对作业人员的损害。

     

/