离子色谱法测定空气中氟化物质量浓度的不确定度评定

Uncertainty evaluation of method for determining airborne hydrogen fluoride in workplaces by ion chromatography

  • 摘要:
      目的  建立和运用离子色谱法测定空气中氟化物质量浓度的不确定度评定方法。
      方法  依据国家职业卫生标准GBZ/T 160.36—2004《工作场所空气有毒物质测定  氟化物》和JJF 1059.1—2012《测量不确定度评定与表示》的原理和方法,采用不确定度传播律对各输入分量不确定度进行逐层评定计算。
      结果  工作场所空气中氟化物的浓度为0.52 mg/m3时,在95%的置信水平下,其扩展不确定度为0.06 mg/m3k=2)。评定结果表明,标准采样体积的合成不确定度为0.394 L;氟化物质量浓度的合成不确定度为0.075 9 μg/mL,其中标准工作曲线拟合对测量不确定度贡献最大。
      结论  该方法准确可靠,适用于离子色谱法测定空气中氟化物质量浓度的不确定度评定,测量过程中标准曲线拟合是重要质控点,对检测结果准确度的提高具有指导意义。

     

/